7.4.3 Installation of SYR App and remote control mode

(page 12 , chapter
Install the SYR App
Connect to the All-in-One+ Connect using the remote control mode

7.4.4 Preparation

Close the isolating valve of the connecting flange.

7.4.5. Setting parameters

Start the App, select the All-in-One+ Connect if applicable and click on
„Einstellungen". (settings). You may now enter the basic settings.
Indicate the desired target pressure up to which the heating installation is to be fi lled.
Select the cartridge type (HWE, HVE, HVE Plus).
Select the size of the connected cartridge.
Set the warning threshold for the capacity
No need to indicate soft water hardness when
using HVE or HVE Plus cartridges!

7.4.6 Venting the All-in-One+ Connect

Click on "Fertig" (done) on the top left of the display, then click on "Granulatwechsel"
(granule replacement).
Click on „Weiter" (next).
Confi rm the following message and click on "Weiter" (next).
You do not have to replace granules at this stage!
This instruction is not valid for the initial fi lling!
Assembly, commissioning, operation and maintenance
7.1.).
Initial commissioning can only be
carried out in this state!
(we recommend: 10% - factory
All-in-One+ Connect
(page 12 , chapter
7.2.).