13.5. Replacing the granules
If the granules in the water conditioning cartridge are used up, the cartridge can be refi lled with new, fresh granules.
•
Empty the cartridge and rinse it thoroughly with water before refi lling it with new granules!
•
Fold the supplied funnel, insert the lance
to connect the funnel and the cartridge.
•
Place the funnel on the opening of the cartridge and center the lance
The opening of the lance is closed at the same time by the centering disk so that no granules can enter from the top during the fi lling
process.
•
Now fi ll the corresponding granules into the cartridge using the funnel,
and remove the centering disk and the funnel afterwards and screw
down the newly fi lled cartridge.
The used granules can be discarded
as residual waste!
into the cartridge and screw together the centering disk
in the cartridge with the mandrel
through the funnel
so as
of the centering disk
.
35