13.2. Maintenance of the pressure reducing valve
The pressure reducing valve has to be serviced annually according to DIN EN 806, Part 5. This includes a functional check and, if necessary,
the cleaning or replacement of the pressure reducer cartridge.
•
Close the isolating valves upstream and downstream of the All-in-One+ Connect
•
Remove the outer casings.
•
Remove the clip
and pull the entire
control unit
upward.
•
Unscrew the pressure reducer cartridge
•
Clean the pressure reducer cartridge or replace the cartridge if it is defective.
Re-install in reverse order.
Attention!
Possible material damage due to improper care!
•
Do not clean the synthetic parts with care products that contain solvents.
by using the ring spanner
(4807.00.906).
(page 30
and
).
31