8
8.1 Electrical connection
1.
2.
8.2 Venting
1.
2.
34
INFO! To ensure the safety, functionality and efficiency
of the circulation pump, use only the supplied thermal
insulation shell.
INFO! The device must be able to be switched off after
installation via an accessible plug or switch in the fixed
wiring. When the pump is connected to the heat genera-
tor control system, it must be possible to switch it off.
CAUTION! If the cable is damaged, the product must
be replaced immediately, as the cable is not replacea-
ble. Further use of the circulation pump is not permit-
ted in this condition.
COMMISSIONING
Plug the Euro plug into the socket.
If necessary, establish a power supply. The pump starts
running immediately.
Ensure air-free circulation.
Until pump runs noise-free, to aid in venting Turn the pump
on and off several times and open the hot water tap several
times.