5.2 Daten
Max. head
Max. flow rate
Electr. Connection
Power consumption
Protection class
Compressive strength
Temperature resistance
Media temperature up to
Ambient temperature up to
Permissible water hardness
Dry-running protection
Opening pressure check valve
5.3 Q/H-diagram
1,2
1,0
0,8
0,6
0,4
0,2
0,0
0
100
CPBA2
200
300
400
Flow rate Q [I/h]
1,2 mWS
700 l/h
1~115–230V / 50–60Hz
7 watts
IP 42
10 bar (1000 kPa)
95 °C
75 °C
40 °C
unlimited
yes
20 mbar
CPB2
500
600
English
700
29