P U M P E N G R U P P E N C S P G U 2 5 / C S P G M 2 5 TECHNISCHE INFORMATION FÜR MONTAGE UND BETRIEB P U M P G R O U P S C S P G U 2 5 / C S P G M 2 5 TECHNICAL INFORMATION FOR INSTALLATION AND OPERATION...
I N H A LT S I C H E R H E I T S H I N W E I S E 1 P U M P E N G R U P P E N U K A R B E I T E N A N D E R A N L A G E : Anlage spannungsfrei schalten und auf 2 P U M P E N G R U P P E N M K...
Seite 3
125 mm Bauteile aus: Stahl, Messing, EPP-Isolierung Abmessung: ca. H 420 x B 250 x T 255 mm Dichtmaterialien: PTFE, asbestfreie Faserdichtung, EPDM Temperaturanzeige: 0 bis 120 °C Einsatztemperatur: bis 110 °C Betriebsdruck: PN 6 kVs – Wert: KBN Rechtsausführung: CSPGU25...
Seite 4
2 P U M P E N G R U P P E N M K 2 P U M P E N G R U P P E N M K ( G E M I S C H T E R K R E I S ) T E C H N I S C H E D AT E N : oberer Anschluss: 1“...
Seite 5
P U M P E N G R U P P E N - P U M P G R O U P S 3 M O N TA G E 3 M O N TA G E 3 . 1 W A N D M O N TA G E Bei der Montage der Pumpengruppe an Vor- und 1.
Seite 6
4 M I S C H E R 4 M I S C H E R Die Lage des Bypasses geht aus der Abbildung hervor. Am Bypass lässt sich die Vorlauf-Temperatur durch Beimengung von Rücklaufwasser absenken. Die Einstellung des Bypasses ist stufenlos möglich. Dazu muss die Sicherheitsschraube (1) ca.
P U M P E N G R U P P E N - P U M P G R O U P S 5 T H E R M O M E T E R W E C H S E L 6 S C H W E R K R A F T B R E M S E 7 S E R V I C E - H I N W E I S E 5 T H E R M O M E T E R W E C H S E L...
TA B L E O F C O N T E N T S S A F E T Y N O T E S 1 P U M P G R O U P U K W O R K I N G O N T H E S Y S T E M : Switch off the power to the system and check 2 P U M P G R O U P S M K that it is switched off (e.g.
Approx. H 420 x B 250 x D 255 mm Sealing materials: PTFE fiber joint free of asbestos Temperature display: from 0 up to 120 °C Operating temperature: up to 110 °C Pressure: PN 6 Kvs values: KBN right hand type: CSPGU25...
4 M I X E R 4 M I X E R The location of the bypass can be seen on the illustration. The advance temperature can be reduced at the bypass by adding reflux water. The bypass setting is continuously variable. The security screw (1) must be loosened by approximately 1 mm.
P U M P E N G R U P P E N - P U M P G R O U P S 5 C H A N G I N G T H E R M O M E T E R 6 G R AV I T Y B R A K E 7 S E R V I C E T I P S 5 C H A N G I N G T H E R M O M E T E R...
Seite 14