17. Troubleshooting
The table below contains a list of error symptoms and explains what you can do to solve the problem if your tool
fails to work properly. If the problem persists after working through the list, please contact your nearest service
workshop.
Problem
Saw blade gets loose after turn-
ing off the motor
Motor does not start
Wrong rotational direction
No motor output, turns off auto-
matically
Burns on the cutting surface
Possible cause
Fastening nut tightened insuffi-
ciently
Failure main fuse
Extension cable defect
Connections on the motor or
switch defect
Motor or switch defect
Capacitor defect
Changed phase
Cross section of extension cable
is too low
Overload by dull saw blade
Dull saw blade
Wrong saw blade
www.scheppach.com
Help
Tighten fastening nut, M20 left-handed
thread
Check the mains fuse.
Replace the extension cable
Have it checked by an electrician
Have it checked by an electrician
Have it checked by an electrician
Have the polarity of the wall socket
changed by an electrician
See "electric connection"
Insert a sharpened saw blade
Insert a sharpened saw blade
Insert correct saw blade
GB | 29