Important, absolutely read
1.

Safety and Operating Instructions

1. General
In operation, drive converters, depending on their degree of
protection, may have live, uninsulated, and possibly also
moving or rotating parts, as well as hot surfaces.
In case of inadmissible removal of the required covers, of
improper use, wrong installation or maloperation, there is
the danger of serious personal injury and damage to property.
For further information, see documentation.
All operations serving transport, installation and
commissioning as well as maintenance are to be carried
out by skilled technical personnel (Observe IEC 364 or
CENELEC HD 384 or DIN VDE 0100 and IEC 664 or DIN/
VDE 0110 and national accident prevention rules!).
For the purposes of these basic safety instructions, „skilled
technical personnel" means persons who are familiar with
the installation, mounting, commissioning and operation
of the product and have the qualifications needed for the
performance of their functions.
2. Intended use
Drive converters are components designed for inclusion in
electrical installations or machinery.
In case of installation in machinery, commissioning of the
drive converter (i.e. the starting of normal operation) is
prohibited until the machinery has been proved to conform
to the provisions of the directive 89/392/EEC (Machinery
Safety Directive - MSD). Account is to be taken of EN 60204.
Commissioning (i.e. the starting of normal operation) is
admissible only where conformity with the EMC directive
(89/336/EEC) has been established.
The drive converters meet the requirements of the Low-
Voltage directive 73/23/EEC. They are subject to the
harmonized standards of the series DIN EN 50178/VDE
0160 in conjunction with EN 60439-1/ VDE 0660, part 500,
and EN 60146/ VDE 0558.
The technical data as well as information concerning the
supply conditions shall be taken from the rating plate and
from the documentation and shall be strictly observed.
3. Transport, storage
The instructions for transport, storage and proper use shall
be complied with.
The climatic conditions shall be in conformity with EN
50178.
4 Installation
The installation and cooling of the appliances shall be in
accordance with the specifications in the pertinent
documentation.
34
Safety and Operating Instructions
for drive converters
(in conformity with the Low-Voltage Directive 73/23/EWG)
The drive converters shall be protected against excessive
strains. In particular, no components must be bent or
isolating distances altered in the course of transportation
or handling. No contact shall be made with electronic
components and contacts.
Drive converters contain electrostatic sensitive components
which are liable to damage through improper use. Electric
components must not be mechanically damaged or
destroyed (potential health risks).
5. Electrical connection
When working on live drive converters, the applicable na-
tional accident prevention rules (e.g. VBG 4) must be
complied with.
The electrical installation shall be carried out in
accordance with the relevant requirements (e.g. cross-
sectional areas of conductors, fusing, PE connection). For
further information, see documentation.
Instructions for the installation in accordance with EMC
requirements, like screening, earthing, location of filters
and wiring, are contained in the drive converter
documentation. They must always be complied with, also
for drive converters bearing a CE marking. Observance of
the limit values required by EMC law is the responsibility of
the manufacturer of the installation or machine.
6. Operation
Installations which include drive converters shall be
equipped with additional control and protective devices in
accordance
with
the
requirements, e.g. act respecting technical equipment,
accident prevention rules etc.. Changes to the drive
converters by means of the operating software are
admissible.
After disconnection of the drive converter from the voltage
supply, live appliance parts and power terminals must not
be touched immediately because of possibly energized
capacitors. In this respect, the corresponding signs and
markings on the drive converter must be respected.
During operation, all covers and doors shall be kept closed.
7. Maintenance and servicing
The manufacturer's documentation shall be followed.
KEEP SAFETY INSTRUCTIONS IN A SAFE PLACE!