CP.31 Relay output 1 / function (terminals X2A.24...26)
CP.32 Relay output 2 / function (terminals X2A.27...29)
The switching level of CP.31 is pre-set to 100,00.
The switching level of CP.32 is adjusted by CP.33!
Value Function
0
No function (generally off)
1
Generally on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (without auto-reset)
6
Warning or error message at abnormal stopping
7
Overload pre-warning
8
Overtemperature alert signal power stage
9
External Overtemperature alert signal motor
11
Overtemperature alert signal interior OHI
12
Cable breakage 4...20 mA on analog input 1
14
max. constant current (Stall, CP.25) exceeded
15
max. ramp current (LA-Stop, CP.24) exceeded
16
DC-braking active
20
Actual value = set value (CP.3 = Fcon, rcon; not at noP, LS, error, SSF)
21
Accelerate (CP.3 = FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization (CP.6) > switching level
25
Active current > switching level
26
Intermediate circuit voltage (CP.7) > switching level
27
Real value (CP.1) > switching level
28
Set value (CP.2) > switching level
31
Absolute set value at AN1 > switching level
32
Absolute set value at AN2 > switching level
34
Set value at AN1 > switching level
35
Set value at AN2 > switching level
40
Hardware current limit activated
41
modulation on
44
Inverter status > switching level
45
Power stage temperature > switching level
46
Motor temperature > switching level
47
Ramp output value > switching level
48
Apparent current (CP.4) > switching level
49
Forward running (not at nOP, LS, abnormal stopping or error)
50
Reverse running (not at nOP, LS, abnormal stopping or error)
63
Absolut ANOUT1 > switching level
64
Absolut ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
70
Driving current active (safety relay)
73
Absolute active power > switching level
74
Active power > switching level
No listed values are only for application mode.