Notes:
*
If the measured resistance value exceeds the maximum
value of the range selected, 1 appears flashes. This
indicates an overload. Select a higher range. In this
mode, the beeper does not sound.
*
When you short the test leads in the 200 range, your
meter displays a small value (no more than 0.3). This
value is due to your meter's and test leads internal
resistance. Make a note of this value and subtract it from
small resistance measurements for better accuracy.
*
If in 200, please short the test leads and measure wine
resistance. And then subtract the resistance from the
value measured.
*
It is normal to display 10M when the test leads shorted
in range 2000M, it will not affect the accuracy and shall
be subtracted from the value measured. For example:
The object resistance is 1000 M, the reading value is
1010M, then the correct value shall be
1010M – 10M = 1000M.