Product Description
2.3
Technical data
2.3.1
230 V class
Inverter size
Housing size
Phases
Output rated power
Max. rated motor power
Output rated current
Output rated current UL
Max. short time current
OC-tripping current
Rated input current
Rated input current UL
Max. permissible mains fuse (type gG)
Rated switching frequency
Max. switching frequency
Power dissipation at nominal operating
Power dissipation at DC operating
Stand still current at 4 kHz
Stand still current at 8 kHz
Stand still current at 16 kHz
Minimum braking resistor
Maximal braking current
Rated input voltage
Input voltage range U
Input voltage range at DC operating
Mains frequency
Output voltage
Output frequency
Max. motor line length shielded at kHz
Max. motor line length shielded at 8 kHz
Max. motor line length shielded at 16 kHz
Max. current before the OL2 function triggers (not at F5 in operating mode v/f)
1)
This data is only valid for units with internal braking transistor (see "Unit identification")
2)
Protection in accordance with UL see annex B
3)
IT system optional
4)
Phase conductor grounded mains are only permissible without HF filters
5)
The voltage at the motor is dependent on the series-connected units and on the control method (example see annex A.2)
6)
The actual output frequency is depending on the parameterisation. The output frequency is to be limited in such
7)
way that 1/10 of the switching frequency is not exceeded. Output frequencies above 599 Hz are possible by
changing the operating mode at control type „BASIC" (xxF5Bxx-xxxx) as well as for special devices on request.
This devices are subject to export authorisation according to entry 3A225 Annex I of the Dual-Use Regulation
and they are labeled accordingly on the delivery note. The output frequency is limited to max. 599 Hz for all other
control types.This devices are not subject to export authorisation.
Site altitude maximal 2000 m above sea level. With site altitudes over 1000 m a derating of 1 % per 100 m
must be taken into consideration.
in
07
GB
1
3
[kVA] 1.6
[kW] 0.75
[A]
4
[A] 4.2
[A] 7.2
[A] 8.6
[A] 8 5.6 14 9.8 20 14
[A] 8 5.8 14 9.5 20 13.5 21
[A] 20 16 20 16 25 20
3)
[kHz]
16
[kHz]
16
[W] 100
[W]
90
[A]
4
1)
[A]
4
1)
[A]
4
1)
[Ω]
56
2)
[A] 7.5
2)
[V]
[V]
[V DC]
[Hz]
[V]
[Hz]
7)
[m] 100
[m]
50
[m]
20
09
10
GB
GB
1
3
1
3
2.8
4.0
1.5
2.2
7
10
6.8
9.6
12.6
18
15.1
21.6
16
16
16
16
130
170
120
155
7
10
7
10
7
10
47
33
9.5
12
230 (UL: 240)
180...260 ±0
250...370 ±0
50...60 ±2
3 x 0...U
in
0...400
100
100
100
GB - 7
12
GB
3
6.6
4
16.5
15.2
29.7
35.6
23
25
8
16
210
185
16.5
16.5
10
27
15