Parameter Description
r21
Mode by means of which an operating cycle is started
based on temperature rather than on time
0 = automatic (that is by means of the test to check the
correct activation of the probe)
1 = manual (that is by pressing and releasing the POS-
ITIVE BLAST-CHILLING or NEGATIVE BLAST-CHILLING
key)
r22
Pre-chilling activation mode
0 = manual (that is by pressing and releasing the POSI-
TIVE BLAST-CHILLING key for 1 second)
1 = both in automatic mode (that is by switching from
"stand-by" to "on", therefore by turning on the device)
and in manual mode (that is by pressing the POSITIVE
BLAST-CHILLING key for 1 second).
r23
Duration of the buzzer activation to report that the test
to check the correct activation of the probe has not
been completed successfully
C0
Minimum time before restoring the power supply after
a power failure that occurred during an operating cycle
and starting the compressor
C1
Minimum time between two consecutive start-ups of
the compressor
C2
Minimum time between switching off the compressor
and switching it back on
C3
Minimum duration of compressor start-up
C4
Duration of compressor shutdown during cell probe
error (code "Pr1") which occurs during conservation;
see also parameter C5
C5
Duration of compressor start-up during cell probe error
(code "Pr1") which occurs during conservation; see also
parameter C4
C6
Condenser temperature above which the condenser
overheated alarm is activated (code "COH")
C7
Condenser temperature above which the condenser
blocked alarm is activated (code "CSd")
C8
Compressor blocked alarm delay (code "CSd")
C9
Duration of compressor start-up during cell probe error
(code "Pr1") which occurs during conservation follow-
ing negative blast-chilling; see also parameter C4
Default
Compressor protections
26
Minimum
Maximum
value
0
0
0
0
2
0
0
0
5
0
3
0
0
0
10
0
10
0
80.0
0
90.0
0
1
0
U.M.
value
1
---
1
---
50
s
240
min
240
min
240
min
240
min
240
min
240
min
199.0
°C/°F
199.0
°C/°F
15
min