Error codes
When some malfunctions happen, the appliances will display
error codes to warn you.
Code
F2
F3
F4
F7
E0
dr
Fault
Ambient temperature
sensor failure
Refrigeration sensor
/refrigeration R1 failure
Freezing sensor failure
Defrost sensor failure
communication fail
Door open
Possible cause
The sensor has a short circuit or
an open circuit
The sensor has a short circuit or
an open circuit
The sensor has a short circuit or
an open circuit
The sensor has a short circuit or
an open circuit
The display board and the power board
cannot communicate for 2 minutes
When the refrigerator door is opened
more than 30 minutes, "dr" will flash in
the refrigerated display area.
Door opening alarm can not be stopped
until the refrigerator door is closed.