5.
Extra possibilities
5.1
Using the emergency battery (optional)
If a battery pack is built into the iM.60, this is kept topped up by a built-in battery charger. The condition of the battery
is tested automatically during the charging process. If it doesn't meet the requirements (<22Volt) any longer, this is
then shown on the internal display as
network so that a control computer that includes the proper functionality can indicate whenever the battery is no
longer reliable.
5.2
Predefined position / adjusting independently
If the control signal or 24 V AC power supply is interrupted, the iM.60 can control the air inlet position independently.
This may be a calculated position or the preferential position (predefined). This predefined position can be set (see
page 13).
No control signal (power)
When the control signal is interrupted, the air inlet will open completely (with a 10-0 V control signal) or close
completely (with a 0-10 V control signal).
A5
(see page 17). The condition of the battery is also available via the I/O
Set Dip 7 to OFF.
Gnd