M16 cable gland

Use a suitable cable to ensure ingress resistance of the M16 cable gland.
If the M12 connectors are used for the device supply and CAN connection, close
the terminal chamber with the supplied M16 cover plug (remove the cable gland
and insert the M16 cover plug).

Definition of short-circuit and overload protection

• Short-circuit test:
All outputs must withstand a short-circuit current limited to 60 A flowing
between output and ground (GND) or supply voltage (+V
Test duration: 3 minutes
• Overload test:
Outputs must not be destroyed by a 100 % overload.
(e.g. nominal switching current I
Test duration: 5 minutes
Fuses
To protect the whole system (wiring and module) the individual electric circuits
are to be protected using fuses according to the type of connection and jumper
settings. The M12 plugs are designed for max. 4 A, the clamps for max. 16 A.
Example
Connection (see also page 31)
1
Supply via M12 CANin/CANout plug
2
Supply via clamps
(not via M12 CANin/CANout plug)
3
Separate supply via clamps
and M12 CANin/CANout plug
4
Supply via clamps
(via M12 CANin/CANout plug)
®
CAGE CLAMP
connection technology
= 2 A → 100 % overload = 4 A)
N
Schraubendreher
Screwdriver
Leiter
Wire
C
M
OMPACT
ODULE
).
BB
Jumpers
3+4 / 5+6+7
3+4 / 5+6
6+7
6+7
1. Insert screw driver and tilt slightly.
(spring opens)
2. Insert wire.
3. Remove screw driver.
(spring closes)
M
CR2032
ETAL
Fuse
4 A
16 A
16 A
4 A
16 A
4 A