1.5 Scope of supply and accessories ACW 18/24 G
Designation
Scope of supply, indoor units
Indoor unit ACW 18 G
Indoor unit ACW 24 G
Infrared remote controller
Batteries
Installation plate
Threaded bolts
Wall mounting unit RC
Rawlplugs
Installation instructions
Instructions for use
Scope of supply, outdoor units
Outdoor unit CU 18 G
Outdoor unit CU 24 G
Outdoor unit CUR 18 G
Outdoor unit CUR 24 G
Outdoor unit CUK 218 ME
Outdoor unit CUK 318 ME
Accessories (not included in scope of supply)
Refrigerant pipes line (with thermal insulation and flare nuts)
Liquid lines for all type series
Diameter 1/4" (6 mm)
Diameter 1/4" (6 mm)
Diameter 1/4" (6 mm)
Diameter 1/4" (6 mm)
Suction lines for CU 18 G, CUR 18 G, CUK 218 ME and CUK 318 ME
Diameter 1/2" (12 mm)
Diameter 1/2" (12 mm)
Diameter 1/2" (12 mm)
Diameter 1/2" (12 mm)
Suction lines for CU 24 G, and CUR 24 G
Diameter 5/8" (16 mm)
Diameter 5/8" (16 mm)
Diameter 5/8" (16 mm)
Diameter 5/8" (16 mm)
Nipples available for extension of two lines
"Low ambient kits.".
for CU 18 G, CU 24 G
for CUK 218 ME, CUK 318 ME
Wall bracket, for fastening outdoor units
CU 18 G, CU 24 G
CUK 218 ME, CUK 318 ME
Thermal insulation tape to cover over the joints between "split" pipe and appliance
Condention water pump to remove condensation water (dimensions H x B x T in mm)
PK 5
PK 7
22
Number Application
1
Indoor installation
1
Indoor installation
1
Indoor unit
2
1
4
1
4
2
2
1
Outdoor installation
1
Outdoor installation
1
Outdoor installation
1
Outdoor installation
1
Outdoor installation
1
Outdoor installation
1
Length 1,5 m
1
Length 4 m
1
Length 7 m
1
Length 10 m
1
Length 1,5 m
1
Length 4 m
1
Length 7 m
1
Length 10 m
1
Length 1,5 m
1
Length 4 m
1
Length 7 m
1
Length 10 m
1
Down to -15 °C
1
Down to -15 °C
2
Up to 72 Kg
2
about 72 Kg
1
Self-adhesive. 3 x 150 mm
1
60 x 75 x 50 u. 30 x 40 x 59 150784
1
177 x 270 x 125
1.6 Specifications and standards
When setting up and installing the units,
Order No
the following specifications and standards
must be respected.
073419
073420
Electricity side:
- VDE 0100
Provisions for installation of power
current systems up to 1000 V.
- EN 60-335
Safety of electrical equipment for
domestic use and similar purposes
- VDE 0701
073427
Specifications for the maintenance,
073428
modification, and inspection of used
073431
electrical equipment.
073432
072664
- VDE 0185
072666
Lightning protection units
- EMC Guideline 89/336/EEC
- Low-voltage Guideline 73/23/EEC
145637
114939
- TAB
114940
Technical Connection Specifications for
117996
connection to the low-voltage network.
145638
- Supplementary provisions from the
114944
electricity supply company responsible.
117945
139292
Coolant medium side:
072407
- EN 378 E (DIN 8975)
157204
Technical safety and environmentally-
114947
relevant requirements
117997
- VBG 20
Cooling systems
161014
General:
072767
- TA (Technical Directive) Noise
071565
Technical Directive for protection against
073228
noise
071566
164907