Mounting and Installation
8.4 Installing a heat shield underneath the hob
When installing the hob above a drawer, furniture compartment
or similar, observe the following precaution according to the installa-
tion instructions:
• Install a protective plate made of heat-resistant material
(e.g. perforated sheet metal to ensure ventilation) at a distance
of at least 50mm below the hob (See illustration).
• When using adhesive, ensure a temperature resistance of 150°C.
• Make sure that the space between the hob and the protective plate
is sufficiently ventilated.
B
  ATTENTION!
Risk of injury and damage!
To avoid serious injury or damage from heat,
electricity or functional elements (such as fans),
make sure that the connection cable
and the underside of the hob are no longer
accessible after installation (also e.g. through
cupboard doors, drawers, etc.)!
64
A
B
1 Hob
1
2 Worktop /
built-in furniture
2
3 Protective plate
3
A min. 50 mm
B min. 5 mm