Herunterladen Inhalt Inhalt Diese Seite drucken

Overview Of Error Outputs - Fronius Magic Wave 2600 Fuzzy Bedienungsanleitung

Schweißgleichrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. OVERVIEW OF ERROR OUTPUTS

ERROR-Number
A
V
0 - t
E R R
X 0 2
E R R
X 0 3
E R R
X 0 4
E R R
X 0 5
E R R
X 0 6
E R R
X 0 7
E R R
X 0 8
E R R
X 0 9
E R R
X 1 0
E R R
X 1 1
E R R
X 1 2
E R R
X 1 3
U - P
E R R
X 1 6
E R R
X 1 7
E R R
X 1 8
E R R
X 1 9
E R R
X 2 0
E R R
X 2 1
X = 0
X = 1
Overtemperature indicator
Short-circuit in temperature sensor
Break in line to/from temperature-sensor
Hardware error (timer module 82C54)
HALL compensation error
I
compensation error
Comm
RAM-access error
EEPROM-access error
Secondary overvoltage error
External error (only for robots)
Hall-Offset error (CAL)
ADC Offset error
ADC Gain error
Primary overvoltage or undervoltage
Cooling cycle error
Primary overcurrent error
Supply error (+5V, +15V)
Serial transmission error
Power module error (is not plugged in)
Stack-Overflow
Error message from commande UTMS1 (MW2600 control-board)
Error message from Interface UTI1A (MW2600 interface-board)
Description of error
and the display are lit up at the same time
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis