8.10.5

Oscilloscope measurement functions

Measurement
Measuring
functions
range
*)
Secondary voltage
5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
AC coupling
200 mV – 5 V
Power
2 A
5 A
10 A
20 A
30 A
Power
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on
*)
the base line.
8.10.6

Oscilloscope functions and specifications

Function
Input coupling
CH1/CH2
Input impedance
CH1/CH2 (to ground)
Electric impedance
CH1/CH2 (electrically isolated)
Bandwidth
CH1/CH2 (to ground)
Bandwidth
CH1/CH2 (electrically isolated)
Bandwidth
1000 A amps clamp
Bandwidth
30 A amps clamp
Bandwidth
Secondary measuring sensor
Bandwidth
Connection cable term. 1,
Time ranges
(referenced to 500 sampling
points)
Time ranges
(referenced to 1 sampling point)
Time base accuracy
Vertical accuracy
Device without sensors
R Offset error for ranges
> 1 V
R Offset error for ranges
200 mV – 1 V
Vertical resolution
Memory depth
Scan rate per channel
(to ground)
Scan rate per channel
Robert Bosch GmbH
Sensors
Secondary
Measuring sensor
Connection
cable, term. 1
CH1 / CH2 multi
measurement cable
Battery B+/B– cable
Amps clamp 30 A
Amps clamp 1000 A
Specification
AC/DC
1 MOhm
1 MOhm (5 – 200 V)
10 MOhm (200 mV – 2V)
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 100 kHz = 200 mV – 2 V
> 500 kHz = 5 V – 200 V
> 1 kHz
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0,01 %
± 2 % of measured value
± 0,3 % of measuring range
± 5 mV
10 bit
4 Mega sampling values
or 50 curves
40 Ms/s
1 Ms/s
Technical data | FSA 500 | 31 |
1 689 989 411
en
|
2023-03-24

Werbung

Inhaltsverzeichnis
loading