| 22 | FSA 500 | Product description
3.4

Optional accessories

Information on optional accessories, such as vehicle-
specific connection cables, extra measurement cables
and connection cables can be obtained from your
Bosch authorized dealer.
3.5

Product description

The FSA 500 consists of the measuring unit with
internal battery supply and a power supply unit with
power supply cable for supplying the measuring unit
and charging the internal storage battery. The USB
connecting cable or Bluetooth USB adapter is used
for connection to DCU 120, DCU 220 or a PC/laptop.
Various sensor cables are also supplied for measured
value recording.
DANGER – Risk of tripping when
transporting and taking measurements
with the FSA 500 and the sensor cables!
The sensor cables represent a greater
tripping hazard during transportation and
measurement.
Always remove the sensor cables prior to
transportation!
Route the sensor cables such that there
is no risk of tripping.
DANGER – Risk of injury from unexpected
closing of the hood!
If the FSA 500 is suspended from the hood,
there is a risk of injury from unexpected
closing of the hood if it is not firmly fixed
in position or if the gas-filled struts are too
weak to support the additional weight of the
FSA 500 and the connected cables.
Make sure the open hood is firmly in
position.
!
The FSA 500 could fall on the ground, for example,
if not properly mounted. This could then result in
damage!
|
1 689 989 411
2023-03-24
3.5.1

Front view FSA 500

1
6
BOSCH
4
A
2
Fig. 1:
Front view FSA 500
1 Carrying strap with hook
2 LED A: Status light
3 LED B: Charge indicator
4 On/Off switch
5 Sensor bracket
6 USB port
The various sensor connection cables can be secured
at the sensor holder.
3.5.2

Sensor connecting cable symbols

Icon
Sensor
Battery B+/B– cable
Universal secondary measuring sensor
Amps clamp
CH1 and CH2 multi measurement cables
Clip-on trigger or adapter cable for clip-on sensor
Temperature sensor
Connecting cable term. 1 / term. 15
2
3
4
FSA
500
Powered by
ESI[tronic]
1
5
459903-03_Ko
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis