Connection panel FSA 500

DANGER – Risk of electric shock from
excessively high measurement voltage!
The measurement of voltages in excess of
200 V using CH1 / CH2 multi measurement
cables will result in injury, heart failure or
fatal electric shocks.
CH1 / CH2 multi measurement cables are
only to be used for measuring voltages up
to max. 200 V.
Never use CH1 / CH2 multi measurement
cable to measure mains or similar
voltages.
459903-02_Ko
1
2
3
4
5
Fig. 2:
Connection panel FSA 500 (viewed from underneath)
Item
Color code
Connection
1
Red/black
Battery B+/B‒ cable
(battery B– cable for vehicle
ground)
2
Green or
Secondary measuring sensor or 30 A
white or
amps clamp or 1000 A amps clamp
yellow
or adapter cable 1 681 032 098 with
fluid pressure sensor (both special
accessories)
3
Green or red
CH2 multi measurement cable
or yellow
or 30 A amps clamp or
1000 A amps clamp
4
Green or blue
CH1 multi measurement cable
or yellow
or 30 A amps clamp or
1000 A amps clamp
5
-
Coupling with hose assembly
(atmospheric pressure
measurement)
6
-

Remote trigger

7
White/black
Clip-on sensor or adapter
cable 1 684 465 513 for clip-on
sensor1)
8
Blue/white
Oil temperature sensor, air and
IR temperature sensor (special
accessories)
9
Yellow /
Connecting cable term. 1/term.
green
15/EST/TN/TD
10
-
Power supply port
11
-
-
Connection for charging station
(special accessory)
For speed measurements with a clip-on sensor, the adapter cable
1)
1 684 465 513 must always be connected between the FSA 500
socket (item 7) and the connection cables for the clip-on sensor.
The color codings on the connection cables refer to the correct
2)
connection at the FSA 500.
Robert Bosch GmbH
6
7
8
9
10
11
2)
Product description | FSA 500 | 23 |
3.5.4

LED Indicators

LED A: Status light
State
LED A
Not lit
FSA 500 off.
Red light
The FSA 500 starts up.
Flashing
FSA 500 on, but not yet ready for operation.
white (1 Hz)
No data link with PC/Laptop.
Flashing
FSA 500 is ready for operation.
green (1 Hz)
Data link to PC/Laptop established via USB.
Flashing
FSA 500 is ready for operation.
blue (1 Hz)
Data link to PC/Laptop established via Bluetooth.
Flashing red
Firmware error.
(4 Hz)
FSA 500 not ready for use.
LED B: Charge indicator
State
LED B
Not lit
No external power supply
connected. Voltage supply
via battery.
Violet light External voltage supply
connected. Storage battery
being charged.
Blue light
External voltage supply
connected. Storage battery
is charged.
Red light
External voltage supply
connected.
Possible cause of trouble:
R Battery temperature >45 °C
R Storage battery not
connected
R Battery defective
R Plug defective
3.5.5
Remote trigger
The start soft key (F3) or the stop soft key (F4) in the
FSA 500 CompacSoft [plus] software can be activated
with the button on the remote trigger.
2
1 684 463 828
Fig. 3:
Remote trigger (1 684 463 828)
1 Key
2 Connector for FSA 500
i
For connection see fig. 2, item 6.
3.5.6

Measurement lead with voltage divider

The measurement lead with voltage divider
(1 687 224 301) is used for voltage measurements
up to 60 VDC/30 VAC/300 VACpeak. The
accessory set (1 687 016 118) contains test
prods (1 684 485 496/... 497) and pick-off clips
(1 684 480 435/... 436) as accessories for the
measurement lead with voltage divider. Never use the
measurement lead with voltage divider to measure
mains or similar voltages.
en
Measure
-
-
External voltage
supply can be
disconnected.
Check storage
battery and plug.
Allow the FSA 500
to cool down.
1
459903-04_Ko
|
1 689 989 411
2023-03-24