8.

Technical Data

8.1

Measurement functions

8.1.1

Engine test

Measurement functions
Rotational speed
Oil temperature
U‑Battery
U‑Term. 15
U‑Term. 1
Ignition voltage,
spark voltage
Spark duration
Relative compression over starter current 0 – 200 Ass
U‑Alternator ripple
I‑Starter
I‑Alternator
I‑Glow plugs
I‑Primary
Dwell angle
Dwell period
Ignition point,
Ignition timing with stroboscope
Start of delivery, begin of injection,
Injection timing with stroboscope
Pressure (atmospheric)
Duty cycle t‑/T
Injection time
Pre‑heating time
8.1.2
Multimeter
Measurement functions
Rotational speed
U‑Battery
U‑Term. 15
U‑DC/ACpeak
(min./max.)
I‑1000 A
I‑30 A
Resistance
(R‑Multi 1)
Pressure P‑Air
Oil temperature
Air temperature
Liquid pressure
The measuring range is greater than the permissible input voltage
1)
Robert Bosch GmbH
Measuring ranges
Resolu-
tion
450 min
– 6000 min
10 min
‑1
‑1
100 min
– 12000 min
10 min
‑1
‑1
250 min
– 7200 min
10 min
‑1
‑1
100 min
– 500 min
10 min
‑1
‑1
‑20 °C – 150 °C
0.1 °C
0 – 60 V
0.1 V
0 – 60 V
0.1 V
0 – 20 V
50 mV
±500 V
1 V
±50 kV
100 V
0 ‑ 6 ms
0.01 ms
0.1 A
0 – 200%
0.1%
0 – 1000 A
0.1 A
0 – 30 A
0.1 A
0 – 100%
0.1%
0 – 360 °
0.1 °
0 ‑ 50 ms
0.01 ms
0.1 ms
0 – 60 °KW
0.1 °KW
0 – 60 °KW
0.1 °KW
‑800 hPa – 1500 hPa
1 mbar
0 – 100%
0.1%
0 ‑ 25 ms
0.01 ms
0 ‑ 20 ms
0.01 ms
Measuring ranges
Resolution
as for engine test
0 – 60 V
0.01 V
0 – 60 V
0.1 V
1)
±200 mV – ±20 V
0.001 V
±20 V – ±200 V
0.01 V
1)
±1000 A
0.1 A
±30 A
0.01 A
0 – 1000 Ω
0.001 Ω
1 kΩ – 10 kΩ
0.1 Ω
10 kΩ – 999 kΩ
100 Ω
0.2 hPa – 2500 hPa
0.1 hPa
‑20 °C – 150 °C
0.1 °C
‑20 °C – 100 °C
0.1 °C
0 – 10000 hPa
10 hPa
Technical Data | FSA 740 Edition | 29
Sensors
Connecting cable B+/B–
‑1
Clip‑on sensor, secondary measuring sensor,
‑1
primary connecting cable (UNI 4)
Amps clamp 30A, clip‑on sensor diesel,
‑1
Amps clamp 1000 A (starter current)
‑1
Oil temperature sensor
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4),
Secondary measuring sensor
Primary connecting cable (UNI 4),
Secondary measuring sensor
Primary connecting cable (UNI 4),
Secondary measuring sensor
CH1 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
Primary connecting cable (UNI 4)
Secondary measuring sensor
Amps clamp 30 A
Clip‑on sensor
Clip‑on sensor
Atmospheric pressure sensor
CH1/CH2 multi measurement cable
CH1/CH2 multi measurement cable
CH1/CH2 multi measurement cable
Sensors
Connecting cable B+/B–
Primary connecting cable (UNI 4)
CH1/CH2 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
CH1 multi measurement cable
Atmospheric pressure sensor
Oil temperature sensor
Air temperature sensor
Liquid pressure sensor
Oil pressure sensor
1 689 989 311
en
|
2017-03-06