8.1.4
Oscilloscope measuring functions
Measuring functions
Measuring range
Secondary voltage
5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
AC coupling
200 mV – 5V
Current
2 A
5 A
10 A
20 A
30 A
Current
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on the
*)
zero line.
8.1.5

Oscilloscope functions and specifications

Function
Specification
Input coupling
AC/DC
CH1/CH2
Input impedance
1 MOhm
CH1/CH2
(relative to ground)
Input impedance
1 MOhm (5 — 200 V)
CH1/CH2
10 MOhm (200 mV — 2 V)
(galvanically insulated)
Input impedance CH2
4 MOhm
(switchover)
Bandwidth CH1
> 5 kHz = 200 mV – 2 V
(galvanically insulated)
> 25 kHz = 5 V – 200 V
Bandwidth CH1 (relative
> 1 MHz = 200 mV – 2 V
to ground)
> 5 MHz = 5 V – 200 V
Bandwidth CH2 (relative
> 1 MHz = 200 mV – 2 V
to ground)
> 5 MHz = 5 V – 200 V
Bandwidth CH2 (diffe-
> 30 kHZ
rential measurement)
Bandwidth 1000 A cur-
> 1 kHz
rent clamp
Bandwidth 30 A current
> 50 kHz
clamp
Bandwidth secondary
> 1 MHz
sensor
Bandwidth connecting
> 100 kHz (20 V)
cable term. 1
> 1 MHz (50 V – 500 V)
Time ranges (relative to
10 µs – 100 s
500 scanning points)
Time ranges (relative to
20 ns – 200 ms
1 scanning point)
Time basis accuracy
0,01 %
Vertical accuracy
±2 % of reading
Device without sensors
±0,3 % of measuring range
(Offset error for ranges > 1 V)
or ±5 mV
(offset error for ranges 200 mV – 1 V)
Vertical resolution
10 bit
Memory depth
1 Mega scan values or 50 curves
Scan rate per channel
50 Ms/s
Robert Bosch GmbH
8.2
Sensors
Function
*)
Secondary
Amplitude
sensor
Connecting
Signal shapes
cable term. 1
Frequency range
Multi measuring
Output current
cable CH1 / CH2
(load-dependent)
Connecting
Impedance
cable B+/B–
Symmetry
Current clamp
30 A
Curve generation
Current clamp
Short-circuit resistance
1000 A
to interference voltage
Short-circuit resistance
to interference voltage
R
R
8.�
Function
Input voltage:
Input frequency
Output voltage
Operating temperature
8.4
< 70 dB(A)
8.5
Function
Dimensions H x B x T:
Weight
Technical data | FSA ��� �dition | 2�
FSA ��� �dition | 2�

Signal generator

Specification
-10 V – 12 V
(load < 10 mA) to ground
DC, sinus, triangle, square
1 Hz – 1 kHz
30 mA – 75 mA
ca. 60 Ohm
10 % – 90 %
(triangle, square)
Output rate up to 100,000 values/s,
Resolution 8 bit,
Y-full range adjustable ( bit),
Unipolar / bipolar mode.
< 50 V static
< 500 V / 1 ms dynamic
Automatically switched filter and damping elements
for improvement of signal quality.
Automatic cutoff at short circuit, interference voltage
detection at start of signal generator.
Power pack
Noise emissions
Dimensions and weights
| 2�
en
Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Spezifikation
1785 x 680 x 670 mm
91 kg
1 689 989 078
|
2012-01-20