DESCRIPTION OF THE CONTROL PANEL INPUTS / OUTPUTS

XH02
Output for connecting the beacon and powering accessories
FLASH GND
GND
XH01
XH02
XH03
XH04
XH05
XH06-1/
XH06-2
BAT
RJ45
WIFI
LED1
CLUTH
XH08
XH09
RJ45
RJ11
RF
+24V
FA
FLASH/
GND
+24V/GND + 24V / GND 24V DC accessory power supply out-
GND/FA
24V AC power input
beacon output and 24V DC accessory power sup-
ply fire alarm control unit signalling output
motor power output
24V DC power input
24V DC electromagnetic power supply output
relay outputs
emergency power battery input
communication connector between drive and
control unit
USB connector for connecting the Wi-Fi module
LED lighting supply output on the drive housing
chain transmission protection input
Inputs controlling the safety functions
Inputs for connecting edge protection devices
Communication connector for between the drive
and control unit
Input for connecting auxiliary control cassette
OPEN / STOP/ CLOSE
RF connector for the connection with a radio re-
ceiver module
FLASH / GND output for powering
the beacon 24V DC, max load 0.2A, the
MENU function must be enabled
put, max load 0.2A
GND / FA relay terminal for fire panel (default NO).
Note: the door will be fully opened automatically
when the fire control panel is triggered (regardless
of the position of the door). The door will not be
able to execute any others until the control panel
command signal returns to NO.