SETTINGS OF FUNCTION PARAMETERS IN MENU
2. —
MENU 2
2. 0
Adjustment of closing
speed
60
Adjustment of speed and decelerations
2.0
. 1
. 2
. 3
. 4
. 5
. 6
Note:
Press and hold the SET button for about 6 se-
conds until the display shows 0.- ; then release
the button
- use the + button to select 2. - then briefly
press the SET button to select this parameter
- the display shows 2.0
- then briefly press the SET button to select this
parameter.
High speed, 100% of standard door closing
speed, 50% of soft closing speed.
Medium speed, 90% standard door closing spe-
ed, 40% of soft closing speed.
Low speed, 80% standard door closing speed,
40% of soft closing speed.
Low speed, 70% standard door closing speed,
35% of soft closing speed.
Low speed, 60% standard door closing speed,
35% of soft closing speed.
Low speed, 50% standard door closing speed,
35% of soft closing speed.
After quick programming of the drive with the
"AAS" function (auto-adaptation system), the
closing speed is automatically selected and
optimized to the given door. If you change this
speed, you must set the limit positions again.