SETTINGS OF FUNCTION PARAMETERS IN MENU
6. 2
Setting control
input parameters
PB2-(NO)
68
. 1
. 1
Step by step
OPEN / STOP / CLOSE
. 2
. 2
CLOSE
if the door is fully open
OPEN
if the door is completely closed
OPEN
if the door is partially open
. 3
. 3
ONLY OPEN
for use in fan systems
. 4
. 4
OPEN partially
. 5
. 5
OPEN the door when it is in
closing phase (reverse action)
. 5
Note
is the default setting
6.2
Press and hold the SET button for about 6 se-
conds until the display shows 0.; then release
the button
- use the + button to select 6.; then shortly
press the SET button to select this function
- press the SET button again and the display
will show 6.0 (default)
- use the + button to select 6.2; then briefly
press the SET button to select this function
and display the parameters:
. 1
. 1
Step by step
OPEN / STOP / CLOSE
. 2
. 2
CLOSE
if the door is fully open
OPEN
if the door is completely closed
OPEN
if the door is partially open