SETTINGS OF FUNCTION PARAMETERS IN MENU
6. 6
XH06-1 relay
output settings
72
6.6
Press and hold the SET button for about 6 se-
conds until the display shows 0.;then release the
button
- use the + button to select 6.; then shortly press
the SET button to select this function
- press the SET button again and the display will
show 6.0 (default)
- use the + button to select 6.6; then short press
the SET button to select this function and display
the parameters:
Contact closed when the door is fully open.
. 1
. 2
Contact closed when the door is fully closed.
Contact closed when partial opening
. 3
is reached.
Before the drive starts, the contact is closed (for
. 4
an adjustable time within the range of 1-7 s.)
To change this parameter, press SET and use
the +/- buttons to set the parameter
1
from
to
3
by default - 3 min.
Contact closed while the door is moving. After
. 5
stopping, the contact is open (for an adjustable
time within the range of 1-10 min.) To change this
parameter, press the SET button and using the +/-
buttons set the parameter
1
from
to
A
means 10 min.
3
by default is -3 min.
. 6
Contact closed while the door is moving.
. 7
The contact opens and closes with the frequ-
ency of 1 Hz. Closed during door movement
(additional function for beacon)
. 8
Relay output operation disabled.
. 8
Note:
by default. It is possible to select the
opertion mode of the NO or NC relay.