SETTINGS OF FUNCTION PARAMETERS IN MENU
6. 3
Electric lock control
(electric lock) 24 V DC
. 3
. 3
ONLY OPEN
for use in fan systems
. 4
. 4
OPEN partially
. 5
. 5
OPEN the door when it is in
closing phase (reverse action)
. 5
Note
is the default setting
6.3
Press and hold the SET button for about 6 se-
conds until the display shows 0.; then release
the button
- use the + button to select 6.; then shortly
press the SET button to select this function
- press the SET button again and the display
will show 6.0 (default)
- use the + button to select 6.3; then briefly
press the SET button to select this function
and display the parameters:
. 0
. 0
The electric lock control function
is disabled
. 1
. 1
The electric lock control function is enabled
1 sec. before opening the door, the electric lock
control voltage appears at the output, locking
the bolt (operation time 1.5 sec.)
After 1 sec. before the door is close, the electric
lock control voltage appears at the output,
locking the bolt (operation time 1.5 sec.)
Note
By default, the feature is disabled
69