  • DEUTSCH, seite 86
SETTINGS OF FUNCTION PARAMETERS IN MENU
4. —
MENU 4
4. -
Adjustment of Auto
Close parameters
64
Adjustment of the Auto Close parameters
4.-
0 3
Note:
4. 1
4.2
4.3
Note:
- Press and hold the SET button for about 6 se-
conds until the display shows 0.-; then release
the button
- use the + button to select 4.- then shortly press
the SET button to select this parameter
- press the SET button again
the display shows
using the +/- buttons select a parameter within
0 1
99
to
, which corresponds to the product
with 5 sec. parameter.
For instance: 5 s. x 10 = 50 sec., and then con-
firm with the SET button. The control unit will
automatically shift to parameter
Using +/- buttons select
the mode of operation of the Auto Close func-
tion.
The automatic closing function is enabled. This
means that the AUTO CLOSE button is active.
4. 1
Function
only works with the
fully open door
4.2
Function
also works if the door has
been stopped while opening.
4.3
Function
is enabled in any door opening
position, including stopping during closing
The Auto Close function only works when the
safety input is activated, and the photocells or
light curtains are connected.
- if the security rope has been cut, the countdown
time is stopped
- when the time of automatic closing is appro-
aching, the signal light starts flashing
- the Auto Close function will only work if the
safety devices are working properly