Herunterladen Inhalt Inhalt Diese Seite drucken

krispol STARCUS F50 Montageanleitung Seite 76

Vorschau ausblenden Andere Handbücher für STARCUS F50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 86
SETTINGS OF FUNCTION PARAMETERS IN MENU
8. —
MENU 8
8.0
Device maintenance
notification settings
76
Device maintenance parameter settings
8.0
.0
Press and hold the SET button for about 6 se-
conds until the display shows 0.; then release the
button
- use the + button to select 8. ; then short press
the SET button to select this function. T the
display shows 8.0 (by default), then short press
the SET button to select the parameter.
.0
means that the function is disabled (de-
fault setting).
Use the +/- buttons to set
.1
parameter from
the selected parameter multiplies the fixed
number of cycles x 500
Where A=1O, F=15
E.g.
.1
means lx500=500 cycles,
.2
means 2x500=1000 cycles,
.A
means 10x500=5000 cycles,
.F
means 15x500=7500 cycles.
.8
.F
to
or

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Starcus f70

Inhaltsverzeichnis