1.4.2 'ALARM' calls
'Alarm' calls to the control desk are initiated manually by the PS-mobile holder or automatically
by the PS-mobile itself. Manual alarms are initiated by pressing the red 'manual' alarm button on
the PS-mobile. Automatic alarm calls are generated by the mobile itself when in a motionless
/angled state for a prolonged period of time, or when the 'tear-off ' plug has been removed.
Figure 2 shows a PS-mobile with its 'tear-off ' plug and a table showing the range of PS-mobiles
and their functions.
1.5 Basic functions of the PS-Micro control desk
The control desk performs the following basic functions:
Table 1.1 Basic Functions
1. System Monitoring and Control
The control desk monitors the status of the PS-mobiles.
2. Alarm Processing
In the event of receiving an alarm from a PS-mobile holder , the control desk informs its
operator via audible and visual indications. Its built-in relay contacts can be activated, a
connected printer can be addressed to print out logging information (programmable) and
messages can be sent to assigned pagers (colleague and operator).
The operators display provides relevant information about the alarm-status, for example -
which PS-mobile raised the alarm, the type of alarm and the last two locations of the PS-
mobile, current and previous if location detection is available in your system.
3. Interfacing
The control desk can be interfaced using its built-in relay contacts, or connected to a PC
or printer using its RS232 interface or connected to a Philips Digital Paging DP6000
system.
4. Logging (see Table 7 Section 7.1)
The control desk if set-up for printing can log all calls and operator actions.
One of three logging modes can be programmed:
- Logging OFF (no logging)
- Log SELECT: only programmed logging events are printed
- Log ALL: All logging events are printed.
5. Guard Tour
In systems with location detection, the control desk can be set to print all location
information of selected PS-mobiles, even though logging is set to OFF for all other events.
6. GS Approval
If programmed for GS approval each PS-mobile must be tested by the operator every
time it is taken into operation and after 24 hours of constant use.
7. Programming
Using its RS232 connection, the control desk can be connected to a PC or Laptop
computer. Using the dedicated PS-Micro Utility software package the desk and PS-
mobiles/paging receivers can be programmed.