PS-Micro control desk LBB 6105/00
If the 'Not-Vertical' alarm has
0001
28-02-00
16:30
Eng
been enabled for GS testing
ACTIVATE NOT-VERTICAL ALARM
the following screen is
displayed.
To test the Not-Vertical
alarm, place the PS-mobile
in a stationary horizontal
position for at least 3
seconds until the alarm tone
0001
28-02-00
16:30
is heard.The PS-mobile will
Alarm received, reset NO-VERTICAL alarm
transmit the "Not-Vertical
Alarm Call" to the system
every 6 seconds until reset.
Once received, the desk
display the following screen:
To reset the alarm press the Alarm/Reset button on the mobile (<2 seconds).The LED and
bleep confirmation will stop.The Not-vertical alarm reset call will be transmitted. When all the
alarms have been completed the PS-micro control desk shows the mobile is OK and ready for
use (see below).
If the mobile is placed into its
16:30
0001
28-02-00
storage/charging rack without
MOBILE IS OK
RETURN
having completed its test
sequence, the test sequence
G
will be stopped.
The time-out for the Alarm
Requests is 60 seconds. If the
system receives no response
within these time periods, an
alarm sequence will start.
0001
28-02-00
16:30
again. In this state place the
MOBILE NOT OK DISABLE MOBILE ?
YES
PS-mobile back into its
charging/storage rack (see
G
opposite).
R
R
In a state where the mobile
can not be put in use, the
mobile can be disabled at the
desk by pressing the <B5>
button while the desk shows
the display shown opposite,
or the PS-mobile should be
placed in its storage rack..