Herunterladen Inhalt Inhalt Diese Seite drucken

Philips PS6000 Benutzerhandbuch Seite 22

Ps-micro überwachungsstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PS-Micro control desk LBB 6105/00
4.7 Audible bleep patterns
The diagram shown below gives a graphical view of the bleep patterns emmitted during the
operation the control desk.
Key to Audible bleeps
1. Reception of a 'Priority 3'
alarm.
2. Reception of a Priority 1
and 2 alarm.
3. End of self test carried out
by the control desk.
4. System error (repeat until
Main button (BM) pressed)
5. Operator error (repeated 5
times)
6. New location received from
a PS-mobile in alarm mode.
7. Alarm 'Not acknowledged'
(This signal is emitted when
switching to the next
received alarm in situations
where more than one alarm
is active).
Audible bleep patterns
High
1
Low
Off
200 ms
200 ms
High
Low
2
Off
500 ms
High
3
Low
Off
200 ms
200 ms
High
1900 ms
4
Low
Off
100 ms
High
Repeated 5 x
5
Low
Off
100 ms ON, 100 ms OFF
High
6
Low
Off
200 ms
200 ms
Low
7
Off
100 ms
400 ms
Off
=
0 Hz
Low
=
420 Hz
High
=
440 Hz
18
User Manual
Repeated until <BM>
key pressed
500 ms
Repeated
until <BM>
key pressed (>2 secs)
100 ms
Repeated until acknowledged
by pressing <BM>
100 ms