04.2006
9.5.2
Changes to the function selection parameter (P052) VC(former)
Siemens AG
6SE7087-6KD60
SIMOVERT MASTERDRIVES
The function selection parameter P052 of the firmware versions for the
previous MASTERDRIVES VC units was used to select the various
special functions and start-up steps. In order to make this important
parameter more comprehensible for the user, the function groups
"Special functions" and "Start-up steps" in the CUVC firmware have
now been stored in two different parameters as follows:
P052 Function selection
Fig. 9-6
Division of parameter P052(former) into P060 and P115
In addition to this, the new special function "User parameter" has been
introduced, and the special function "Drive setting" (P052 = 5) has been
subdivided into the functions "Quick parameterization" and "Drive
setting". The new special function "Quick parameterization" involves
parameterization for standard applications, and the new special
function "Drive setting" involves parameterization for expert
applications.
The special function "Download/Upread" (P052 = 3) has been
subdivided into the functions "Download" and "Upread".
P060
Menu selection
0=
User parameter
1=
Parameter menu
2=
Fixed settings
3=
Quick parameterization
4=
Board configuration
5=
Drive setting
6=
Download
7=
Upread
8=
Power section definition
1) Selection in the factory setting menu (P366 Factory setting type, activation with P970)
Operating Instructions
P060 Menu selection
(Special functions)
P115 Calculation of
motor parameters
P052 (former)
--
0=
1)
1=
5=
4=
5=
3=
3=
2=
Parameterizing Steps
Function selection
See parameter list
P060
Return
Param. Reset
Drive Setting
HW Config.
Drive Setting
Download
Download
MLFB input
9-67