Parameterizing Steps
P462 = ?
P463 = ?
P464 = ?
P465 = ?
Sinusoidal filter (P068=1)
or
synchronous motor?
no
yes
P115 = 2
Analog tachometer?
no
yes
Adjust
tachometer
9-58
Enter the acceleration time from standstill up to reference
frequency (P352)
Enter the unit for acceleration time P462
0 = Seconds
1 = Minutes
2 = Hours
Enter the deceleration time from reference frequency
(P352) up to standstill
Enter the unit for deceleration time P464
0 = Seconds
1 = Minutes
2 = Hours
Calculate motor model "Motor identification at standstill"
NOTICE:
Current flows through the motor and the rotor rotates!
After pressing the "P" key, the alarm message "A087" appears.
The converter must be turned on within 20 secs!
Analog tachometer present?
Adjust tachometer
Tachometer to ATI: See operating instructions for ATI
Tachometer to terminal strip: See function diagrams for analog
inputs