8 Putting out of operation

7.2 Welding process

Risk of burns from hot surface
Welding torches become very hot during welding. This may result in serious burns.
► Allow welding torches to cool down after welding.
► Wear the correct protective gloves.

Starting the welding process

Ensure that the device is protected against falling.
1
Ensure that the welding torch neck is securely attached.
2
To start up the magnet, set the magnet lever to "ON".
3
Adjust the speed on the speed controller.
4
Set the weld start signal switch to "I".
5
Set the travel direction switch to the desired direction.
6
If the arc ignition switch is in position "I", then the welding torch will start to weld immediately after the travel
direction switch is actuated.
Stopping the welding process
Set the travel direction switch to "O".
1
Set the weld start signal switch to "O".
2
Switch on/off the device.
3
8 Putting out of operation
► When putting the system out of operation, ensure that the procedures for switching off the welding
components are observed.
Switch on/off the device.
1
Wait until the shielding gas post-flow time has passed.
2
Close the shut-off valve for the gas supply.
3
Switch off the power source.
4
Disconnect the power supply/power source communication connection cable from the device.
5

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
The maintenance cycle is determined by the work environment and by the length of the scheduled intervals
between maintenance of the devices. The maintenance cycle is usually three months. If the device is
operated for more than 8 hours a day, the maintenance intervals should be changed as needed.
Electric shock caused by damaged or improperly installed cables
The use of damaged or improperly installed cables may result in a potentially fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician only.
Risk of injury due to unexpected start
If the device is energised during maintenance, cleaning or disassembly work, rotating parts may
unexpectedly start up and cause crushing.
► Switch off the device.
► Disconnect all electrical connections.