2.8.2 - Realisation of pipe passage holes

If the connection lines arrive from the rear right of the indoor unit, a hole "R" must be made for passage of
the piping, as successively described (see figure X1).
a. Make a 6÷7 mm hole in the centre of the position "R", with slope towards the outdoors of 5% (to allow
condensate to be drained correctly (figure 6).
b. Make the hole "R" using a core drill with the diameter indicated in the table of figure X1.
c. Insert the drain line piping and that of refrigeration into the hole along with the electric connection cable.
If the connection lines arrive from the rear left of the indoor unit, a hole "L" must be made for passage of the
piping (see figure X1).
X
1
L
ø
H
Model
9
12
18

2.8.3 - Piping connection

a. Based on the position of the wall hole with respect to the mounting plate, choose the side from which it
is wished the refrigerant pipes come out from the unit.
b. If the wall hole is located at the side of the internal unit, remove the precut plastic panel from the unit side.
It is possible to use pliers to ease the opening of the precut panel (fig.7).
The refrigerant pipes can come out from the internal unit with four different angles:
• Left side
• Rear side to the left
• Right side
• Rear side to the right
Please refer to figure 7 for further details.
c. Attach the upper bracket present in the rear part of the indoor unit to the upper hook of the fixing bracket
(pos. L - figure 8).
d. Move the unit laterally to ensure it is correctly attached to the fixing hook (7).
e. If the connection pipes are already fitted in the wall, directly proceed with the connection of the drain pipe.
Piping connection is easily performed by lifting the indoor unit and introducing cladding between the same
and the wall (pos. N - figure 8). Remove the cladding once connection has been completed.
f. Push the lower part of the indoor unit towards the wall to attach it to the fixing bracket (pos. M - figure 8).
g. Try and move the indoor unit laterally and vertically to make sure that it is attached securely.
EN - 18
fixing bracket
indoor unit
L
R
mm
mm
101,6
115,6
183,6
123,6
240
143
R
H
ø
mm
mm
47
65
47
65
47
65
ø
H

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nexya s5 e trialNexya s5 e quadriNexya s5 e pentaNexya s5 e duct multi

Inhaltsverzeichnis