please contact the manufacturer.
15. Collected refrigerant must be returned to the fluid supplier in the appropriate
collection cylinder, compiling the corresponding Handover Note of Scraps.
DO NOT mix the refrigerants in the collection units and, in particular, in the cylinders.
16. Make sure that contamination between different refrigerants does not occur when
a reloading equipment is used. The flexible pipes or ducts must be as short as
possible to reduce the quantity of refrigerant inside them to a minimum.
17. Do not drill nor burn the unit.
18. The replaced electric components MUST be suitable and correspond to the appliance
specifications. Every maintenance operation MUST be carried out as described in
this manual. Contact the manufacturer in case of doubt.
19. Apply the following checks:
• The size of the room inside which are located the parts containing the refrigerant, are
in accordance with the current quantity of charge of the refrigerant;
• The ventilation device works correctly and the outlets are not clogged;
• The markings on the machine must always be visible and readable, correct them if not;
• The pipelines ore the components containing refrigerant MUST be installed in a
place where no substance may corrode them, unless the components are built
with materials intrinsically resistant against corrosion or are suitably protected
against this risk.
20. The refrigerating gases are odourless.
21. For disposal and marking (through signs) of the appliance containing refrigerant
gas, please refer to the local regulations.
22. To store the appliance: The packaging for storage must be resistant in order to
avoid that the appliance may take damage and to avoid the possible leakage of
refrigerant gas.
23. Recovered refrigerant must not be discharged in another refrigerating system
unless it has been cleaned and checked.
24. Dismantling MUST be carried out by a qualified technician whom MUST use the PPE
correctly and MUST perfectly know the equipment.
All the refrigerants MUST be recovered safely; always collect a sample of oil and
refrigerant before emptying the circuit.
25. Before starting any dismantling operation:
- Electrically insulate the system.
- Ensure that you have mechanical handling equipment at your disposal to handle
the tanks, if necessary.
- The equipment and recovery tanks MUST be in compliance with the standards.
26. The equipment must be labelled indicating that it has been deactivated and emptied
of refrigerant. The label must be dated and signed. Make sure that on the equipment
are present labels indicating that the equipment contains flammable refrigerant.
27. If the compressors or compressor oils must be removed, it is necessary to check
that they have been extracted safely and at an acceptable level to ensure that the
flammable refrigerant has not remained inside the lubricant. The evacuation process
must be carried out before returning the compressor to the suppliers. To speed up
this process, only electric heating of the compressor body must be used.

0.3 - PROPER USE

• The air-conditioner should be used for the exclusive purpose of producing hot or cool
air (on demand) for the sole purpose of obtaining a comfortable temperature in the room.
• Improper use of the machine (outside and inside units) causing damage to persons,
property or animals relieve OLIMPIA SPLENDID of any liability.

0.4 - HAZARDOUS ZONES

• The climate controllers must not be installed in environments with the presence
of inflammable gases, explosive gases, in very humid environments (laundries,
EN - 7