2.3 - PROCEDURES FOR INSTALLATION OF THE EXTERNAL UNIT

• Install the outdoor unit
MC
• Evacuate the refrigeration system

2.3.1 - Step 1: Select installation location

Install the unit by following local codes and regula-
tions, there may be differ slightly between different
regions. Before installing the outdoor unit, you must
choose an appropriate location. The following are
standards that will help you choose an appropriate
location for the unit.
Proper installation locations meet the following stand-
ards:
• Keep the distances indicated in the figure.
• Good air circulation and ventilation.
• Stable and levelled supporting surface.
• The unit noise must not disturb others.
• Fixing wall able to bear the unit.
• Where snowfalls are envisaged, adopt appropriate measures to prevent ice accumulation and damages
to the unit.
DO NOT install unit in the following locations:
• Near an obstacle which may obstruct the air inlet or outlet.
• Near a public street, crowded areas, or where noise from the unit will disturb others
• Near animals or plants that will be harmed by hot air discharge
• Near any source of combustible gas In a location that is exposed to large amounts of dust
• In a location exposed to a excessive amounts of salty air
2.3.2 - Special considerations for extreme
weather
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the
direction of the wind. If needed, build a barrier in front
of the unit to protect it from extremely heavy winds.
EN - 14
• Connect the refrigerant pipes
MC
• Perform a test run
between different regions.
Strong
wind
L
N
(L1)
(L2)
• Connect the wires
Strong wind
Wind Baffle
Strong wind