Herunterladen Inhalt Inhalt Diese Seite drucken

Attaching/Removing The Flat Spray Nozzle; Initial Start-Up; Working Instructions; Adapter With Threaded Connector - Parkside PTL 4 B4 Originalbetriebsanleitung

Teleskop-lanze für hochdruckreiniger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
hose (17) at the connection for the
telescopic tube (18).
Attaching/removing the
flat spray nozzle
Attaching the flat spray nozzle
• Fix the flat spray nozzle (1) by insert-
ing it and rotating it (bayonet locking
device) on the elbow connector (2).
Removing the flat spray nozzle
• Remove the flat spray nozzle (1) by turn-
ing and pulling it out (bayonet socket)
from the elbow connector (2).

Initial start-up

Working instructions

Be aware of the recoil force when
the water jet commences. Ensure
you are standing firmly and hold-
ing the spray gun firmly. Otherwise
there is a risk of injuring yourself or
other people.
1. Adjust the telescopic tube to the desired
length.
2. Release the rotary lock on the auxiliary
handle (23) and pull the telescopic
tube (4,5,6) out of the preceding tel-
escopic tube (5,6), or main tube (7).
Fix the now extended telescopic tube
(4,5,6) using the rotary lock on the
auxiliary handle (23).
3. Establish a water connection with your
high-pressure cleaner at the water con-
nection (15) on the handgrip (11) of
your telescopic tube.
4. Put the shoulder strap (9) on.
5. Hold the telescopic tube with both
hands on the handgrip (11) and on the
handgrip area (8).
6. If the high-pressure cleaner is activated,
pressing the switch-on lever (20) ejects
high-pressure water from the flat jet
nozzle (1). Once the switch-on lever
(20) is released, the flow of water
stops.
Pressing the switch lock (21) enables
you to secure the telescopic tube
against being unintentional switched
on.
Adapter with threaded
connector
The adapter (25) is intended for use with
PARKSIDE high-pressure cleaners
PHD 100 A1, PHD 100 B2, PHD 100 C2,
PHD 100 D2, PHD 110 D1
PHD 150 A1, PHD 150 B2, PHD 150 C2,
PHD 150 D3
PHD 170 A1, PHD 170 B2
PHDP 180 A1.
1. Insert the adapter into the water con-
nection (15) on the handgrip (11) of
your telescopic tube. You will hear it
click into place.
2. Establish a water connection with your
high-pressure cleaner via the adapter
(25) on the water connection (15) on
the handgrip (11) of your telescopic
tube.

Quick-Connect adapter

(third-party devices)

Quick-Connect adapter (26) with securing
clip (27) for high-pressure cleaners made
by third-party manufacturers.
1. Insert the Quick-Connect adapter (third-
party devices) (26) into the water con-
nection (15) on the handgrip (11) of
GB
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis