  • DEUTSCH, seite 4
GB
your telescopic tube. You will hear it
click into place.
2. Remove by pulling the securing clip
(27) for the Quick-Connect adapter
(third-party devices) (26).
3. Establish a water connection with your
high-pressure cleaner via the adapter
(26) on the water connection (15) on
the handgrip (11) of your telescopic
tube.
4. Secure the connection by inserting the
securing clip into both holes of the
Quick-Connect adapter (third-party de-
vices) (26).

Using detergents

The pressure cleaner was designed for
operation with a neutral detergent based
on a biologically decomposable anionic
tenside. Other detergents or chemical sub-
stances could impair the safety of the pres-
sure cleaner and damage it. Such damage
to the equipment is not covered by the
guarantee.
Cleaning and

Maintenance

Always remove the mains plug of
the high pressure cleaner before
working on the device. There is a
risk of electric shock or injury from
moving parts.

Cleaning

Always keep the device clean. Do
not use any detergents or solvents.
• Only clean the device with a soft brush
or a slightly moist cloth.
14
Maintenance
The device is maintenance-free.
Replacing the high-
pressure hose
Replace a damaged high-pressure
hose.
Removing the high-pressure
hose
1. Detach the flat spray nozzle (1) by turn-
ing and pulling it out (bayonet socket)
from the elbow connector.
2. Remove the safety clip (3)
3. Press and hold the release button (24).
4 Pull the elbow connector out from the
high-pressure hose.
5. Press the release for the high-pressure
hose (
13). Pull away the high-pres-
sure hose (
17) at the connection for
the telescopic tube (
6. Pull the high-pressure hose out of the
telescopic lance through the opening
for the high-pressure hose (
Installing the high-pressure hose
1. Guide the high-pressure hose (17) into
the opening for the high-pressure hose
(10) with the connection for the elbow
connector (19) first.
2. Slide the high-pressure hose (17)
through the main tube (
first, second and third telescopic tube (
6,5,4). Slide the high-pressure hose
(17) until it starts to exit from the third
telescopic tube (4) with the connection
for the elbow connector (19).
3. Slide the angle piece (2) with the high-
pressure hose (17) back across the
third telescopic tube (4) until the two
18).
10).
7) and the

Werbung

Inhaltsverzeichnis