Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC expert-
sand warning: "This is a product of category C2 according to EN 61800-3. This product may
cause radio interference in a residential area. In this case, it may be necessary for the oper-
ator to take appropriate action."
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values
are below those of class A group 1, plus warning: "This type is not suitable for connection to
a public low-voltage network supplying residential buildings. When connecting to a public
low voltage network, radio frequency interference is expected."
Speed regulated
grinding machines
Categorie
Environment
Voltage / Current
EMC knowledge
1.4
Possible dangers caused by the grinding machine
The grinding machine was built using state-of-the-art technology. Nevertheless, there is a resid-
ual risk, as the grinding machine operates with
high speeds,
rotating parts,
one grinding wheel (emission of sparks),
one cleaning brush,
electrical voltage and currents.
We have used design and safety engineering to minimize the health risk to personnel resulting
from these hazards.
If the grinding machine is used and maintained by personnel who are not duly qualified, there
may be a risk resulting from its incorrect or unsuitable maintenance.
INFORMATION
Everyone involved in the assembly, commissioning, operation and maintenance must
be duly qualified,
and strictly follow these operating instructions.
Always disconnect the grinding machine from the electrical power supply before performing
cleaning or maintenance tasks.
WARNING!
The grinding machine may only be used with fully functional safety devices.
Disconnect the grinding machine immediately, whenever you detect a failure in the
safety devices or when they are not fitted!
GB
GU15B │GU18B │GU20B │GU25B
Page 34
®
C1
C2
Residential area
Business area
Industrial area
< 1000 V
no requirement
Installation and commissioning by an EMC expert
Translation of the original instructions
C3
C4
Industrial area
> 1000 V
Version 1.0.2 dated 2019-9-13