26. Installation examples

Rectangular mowing area with one tree
and swimming pool
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing
tree (3), based on a linking section
installed at right angles to the edge.
Swimming pool:
For safety reasons (specified wire
clearance) the perimeter wire (2) is routed
around the pool B.
0478 131 9923 B - EN
Wire clearances: (
11.5)
Clearance to edge: 22 cm
Clearance to the obstacle that can be
travelled on: 0 cm
Clearance around the tree: 24 cm
Clearance to the pond: 100 cm
Programming:
No further adaptation is necessary
following definition of the size of the
mowing area.
Particularities:
Unmown areas around the swimming pool
must be mown manually on a regular basis
or cut using a suitable lawn trimmer.
147