ATTENTION
y The power inputs of the electrical devices provided in
table 3 and 4 were measured using a standard commerci-
ally available wattmeter and the provided value may dif-
fer based on the intensity of the load (e.g. by the exertion
of pressure on the power tools during use). They illustrate
the approximate power input values of standard expec-
ted use of the power tools, which can also be applied to
other types of power tools (e.g. planers and others).
y The listing of specific generator models serves only as
an example from our offer for the purpose of illustrating
the electrical power output of the generators. There are,
however, also other models of our generator or other
brands with the same electrical power output, which
may be used. In the event that the power tools are put
under greater load, it may become necessary to use
a generator with a greater electrical power output than
specified. The specified minimum electrical power out-
put of the generators is for illustration purposes only and
prior to the intended use of a specific generator, the ope-
rating power output of which approaches the specified
power input on the electrical device being used, perform
a measurement with a wattmeter and carry out an ope-
rational test on a sample generator based on the expec-
ted operating load of the electrical device (if possible).
yFrom tables 3 and 4 it is evident that the genera-
tor HERON® 8896416 with an electrical output of
2.5 kW and max el. output of 2.8 kW, which also
applies to HERON® 8896317, is absolutely suffici-
ent for powering the majority of electrical devi-
ces including power tools such as angle grinders,
circular saws, as well as less powerful compres-
sors, electric pumps, etc., under the condition
that only a single power tool is connected to the
generator (see overview of power inputs and the
usable generators farther in the text).
y In the event that the current load of the circuit breaker is
exceeded (see shut-off current of circuit breaker ltrips in
table 1), the lever of this circuit breaker shall be "tripped"
(the lever will be in the down position) and current supply
to the electrical device will be interrupted, or the engine
of the generator will be throttled if the electrical power
output of the alternator is lower than the shut-off current
of the circuit breaker. If this happens, disconnect the
electrical device from the generator and do not connect
this electrical device to the generator, but rather replace it
with an electrical device with a lower current draw (lower
power input) and then "reset" the circuit breaker again.
y In the event that the generator starts to behave in a non-
-standard manner during operation (e.g. sudden reducti-
on in rpm, non-standard noise, etc.), interrupt the supply
of current to the power sockets using the circuit breaker
with the electrical device connected, and if the manife-
station of this non-standard operating behaviour is not
remedied in this way, immediately turn it off by toggling
the power switch to the "OFF" position and identify the
cause of this non-standard behaviour. In the event that
the reason for the non-standard operation is a fault insi-
de the generator, arrange a repair of the generator at an
authorised service centre for the the HERON® brand.
127
VII. Additional
information for the use
of the generator
CONTENT OF OXYGENOUS
COMPOUNDS IN THE FUEL
y The content of oxygenous compounds in lead-free car pet-
rol must meet the current requirements of norm EN 228.
Under no condition prepare the fuel blend yourself but
instead procure it only at a fuel station. Do not modify
the composition of the purchased fuel (excluding the
use of a fuel conditioner). Use only good quality lead-
-free car petrol.
OIL SENSOR AND MONITORING
THE OIL AMOUNT
y The generator is fitted with an oil sensor (fig. 3, position
9) that shuts off the engine when the oil level falls below
a critical limit, and thus prevents damage to the engine
resulting from insufficient lubricati-
on. In the event that the oil level is
low, it will not be possible to start
the generator because it is protected
by an oil level sensor. The level must
be as shown in the pictogram. The
presence of this sensor does not
entitle the operator to omit regular checks of the
amount of oil in the engine's oil tank.
The oil sensor must not be removed from the
generator.
DIGITAL METER OF OUTPUT
VOLTAGE, FREQUENCY AND
OPERATION HOURS.
y The generator is equipped with a digital motor hours
counter from the last start (the counter is automatically
reset to zero when the engine is turned off) as well as
a total motor hours counter (symbol "H") from the first
start of the generator, the output voltage (symbol "V")
and frequency (symbol "Hz"), see description of the
front (control) panel of the generator.
It is possible to use the button on the control panel to swit-
ch between the individual measured values.