Alternating current (A/AC)
8
Range
600.0 µA
6000 µA
60.00mA
600.0mA
6.000A
10.00A
Specified measurement range: 5 - 100% of the measurement range
Overload protection 600 V; frequency range 45 - 400 Hz
Fuses: µA/mA = 2x 0.55 A/240 V resettable, 1x F2 2.5 A/700 V ceramic, internal
resistance approx. <10 Ω
10 A = High-performance FF 10 A/600 V ceramic fuse
≤ 6 A = continuous measurement, >6A = max. 30 s at intervals of 15 minutes
The multimeter may display 3 counts when a measurement input is open.
TrueRMS peak (Crest Factor (CF)) ≤3 CF over the entire range
TrueRMS peak for non-sinusoidal signals plus tolerance:
CF >1.0 - 2.0
CF >2.0 - 2.5
CF >2.5 - 3.0
Resolution
0.1 µA
1 µA
0.01mA
0.1mA
0.001A
0.01A
+ 3%
+ 5%
+ 7%
Accuracy
±(1.3% + 4)
±(1.5% + 4)
±(1.8% + 7)