Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC272 Bedienungsanleitung Seite 73

Digital multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.5.2 Follow the steps below to measure AC currents (A
1. Switch on the DMM and select "10A, mA, or µA" mode.
2. Press SEL/
3. Press the SEL/
4. Select the desired measurement range and connect the corresponding termi-
nals.
Measurement mode
µA
mA
10A
5. Insert the red test lead into the mAµA or 10A max measurement socket. Insert
the black test lead into the COM measurement socket.
6. Connect the two measuring probes (de-energised) in series to the object that
you want to measure (e.g. generator or circuit). The electrical circuit must be
disconnected before you connect the probes.
7. Reconnect the circuit. The measurement will appear on the display.
8. After measuring, disconnect the circuit and remove the test leads from the
measured object. Switch the DMM off.
to switch to AC mode. "AC" will appear on the display.
button again to switch back to DC mode.
Measurement range
0 - 6000 µA
0 - 600 mA
0 - 10 A
Terminals
COM + mAµA
COM + mAµA
COM + 10A
)
73