Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC272 Bedienungsanleitung Seite 92

Digital multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Measuring tolerances
Accuracy in ± (% of reading + display error in counts (= number of smallest points)).
The accuracy is valid for one year at a temperature of +23 °C ± 5 °C, and at a
relative humidity of less than 75%, non-condensing. Temperature coefficient: +0.1 x
(specified accuracy)/1 °C outside the specified temperature range.
The accuracy of measurements may be affected when the multimeter is used in a
high-frequency electromagnetic field.
Direct voltage (V/DC)
1
Range
60.00 mV*
600.0 mV*
6.000 V
60.00 V
600.0 V
*Only available in "mV" mode
Specified measurement range: 5 - 100% of the measurement range
600 V overload protection; Impedance: 10 MΩ (mV: ≥100 MΩ)
The multimeter may display ≤5 counts if a measurement input is short-circuited.
Direct voltage (V/DC) LoZ
2
Range
6.000 V
60.00 V
600.0 V*
92
Resolution
0.01 mV
0.1 mV
0.001 V
0.01 V
0.1 V
Resolution
0.001 V
0.01 V
0.1 V
Accuracy
±(1.2% + 8)
±(0.9% + 8)
±(0.9% + 4)
Accuracy
±(1.7% + 7)