Icons in the display:
1. Date/Time Indicator
2. WHO classification
3. Memory Zones
4. Memory Sequence Number
5. Weak Battery Mark
6. Cardiac arrhythmia icon
7. Pulse Mark
8. Pulse Rate
9. Diastolic Pressure
10. Systolic Pressure
11. Problem shown on the display

4. Prepare measurement

Inserting battery
• Remove the battery cover from
the back of the monitor.
• Insert four AA 1.5 V alkaline bat-
teries. making absolutely sure that
you insert them with the correct
polarity as marked. Never use
rechargeable batteries.
• Replace the battery cover carefully.
If the battery change „
measurement is no longer possible and you must replace all
the batteries. Once batteries have been removed from the de-
vice, the time must be reset.
Used batteries do not belong in the household waste. You are
legally obliged to dispose of the batteries. Dispose of them via
your specialist electrical supplier or local collec ting point for
recyclable waste.
1
2
10
3
9
4
8
Digit height : 20.0mm
6
5
7
Digit height : 23.0mm
" is continuously illuminated,
Normal
Pre-hypertension
Stage 1 Hypertension
Note: Batteries containing pollutant substances
are marked as follows: Pb = Battery contains
lead, Cd = Battery contains cadmium, Hg = Bat-
tery contains mercury.
setting date and time
It is vital to set date and time. Only in this way is it possible to
11
save and subsequently retrieve your measured values with the
right date and time.
Press the " " key and " " to adjust the month. Then press
the " " and " " in turn to adjust the date, hour, minute and
confirm the entry.
Time is shown in 12 hour format.
核准
D C C
Mains operation
You can also operate this device with a mains adapter. No bat-
teries should be in the battery compartment for this. The mains
adapter is available from retailers or from the service address
under order no. 071.03. The blood pressure monitor should
only be used with the mains adapters specified here. The
mains adapter should only be connected to the mains voltage
indicated on the rating plate. Once you have disconnected the
device from the mains, the date and time on the blood pressu-
re monitor are lost. Any measurement results that have been
stored are however retained.

5. Measuring blood pressure

Positioning cuff
Fit the cuff round your bare left up-
per arm. Blood circulation in the
arm should not be restricted by tight
clothing or other objects.
13
Stage 2 Hypertension