Technical Data

Metal Cutting Saw
Article number
3 601 M28 ...
Rated power input
No-load speed
Soft starting
Laser type
Laser class
Weight according to
EPTA-Procedure 01/2003
Protection class
Permissible workpiece dimensions (maximum/minimum) see page 22.
The values given are valid for a nominal voltage [U] of 230 V. For differ-
ent voltages and models for specific countries, these values can vary.
Dimension of suitable saw blades
Saw blade diameter
Blade body thickness
Mounting hole diameter

Noise/Vibration Information

Sound emission values determined according to
EN 61029-2-10.
Typically the A-weighted noise levels of the product are:
Sound pressure level 100 dB(A); Sound power level
113 dB(A). Uncertainty K =3 dB.
Wear hearing protection!
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 61029:
2
2
a
=3.5 m/s
, K=1.5 m/s
.
h
The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 61029 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working pe-
riod.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work pat-
terns.
1 609 92A 0XZ | (3.9.14)
Declaration of Conformity
We declare under our sole responsibility that the product de-
GCD 12 JL
scribed under "Technical Data" is in conformity with all rele-
vant provisions of the directives 2011/65/EU, 2014/30/EU,
... 0..
... 060
2006/42/EC including their amendments and complies with
the following standards: EN 61029-1, EN 61029-2-10,
W
2000
1650
-1
min
1500
1500
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
nm
650
650
70764 Leinfelden-Echterdingen, GERMANY
mW
< 0.39
< 0.39
Henk Becker
1M
1M
Executive Vice President
Engineering
kg
20
20
/II
/II
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 03.09.2014
Assembly
mm
305
mm 1.8–2.5
 Avoid unintentional starting of the machine. During as-
mm
25.4
Delivery Scope
Carefully remove all parts included in the delivery from their
packaging.
Remove all packaging material from the machine and the ac-
cessories provided.
Before starting the operation of the machine for the first time,
check if all parts listed below have been supplied:
– Metal cutting saw with mounted saw blade
– Hex key/cross-head screwdriver 12
Note: Check the power tool for possible damage.
Before further use of the machine, check that all protective
devices are fully functional. Any lightly damaged parts must
be carefully checked to ensure flawless operation of the tool.
All parts must be properly mounted and all conditions fulfilled
that ensure faultless operation.
Damaged protective devices and parts must be immediately
replaced by an authorised service centre.
Stationary or Flexible Mounting
 To ensure safe handling, the machine must be mounted
Mounting to a Working Surface (see figure A)
– Fasten the power tool with suitable screw fasteners to the
Flexible Mounting (not recommended!)
If, in exceptional circumstances, it is not possible to securely
mount the power tool on a work surface, you can improvise by
placing the feet of the saw-table 25 on an appropriate base
(e.g. work bench, flat ground, etc.), without screwing down
the power tool.
EN 60825-1.
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
sembly and for all work on the machine, the power plug
must not be connected to the mains supply.
on a level and stable surface (e. g., workbench) prior to
using.
working surface. The mounting holes 23 serve for this pur-