Error
State
F24
No response to start
command
F25
No response
F26
No response
F27
Drive blocked
F28
No response to start
command
F29
Motor rotates in incor-
rect direction.
F30
Door only runs in
dead man mode for
closing
F31
Door neither opens
nor closes
F34
Door neither opens
nor closes
F35
Door neither opens
nor closes
F40
Extended control
does not respond
F41
Extended control
does not respond
F42
Extended control
does not respond
F43
Extended control
does not respond
F45
RadioBand, wireless
closing edge
F46
RadioBand, wireless
closing edge
F71
Door neither opens
nor closes. Erroneous
wicket door contact.
F72
Door neither opens
nor closes
F73
Door neither opens
nor closes. Testing of
input J4.1/2 failed
F74
Door neither opens
nor closes. Testing of
input J4.3/4 failed
F75
Door neither opens
nor closes. Output
voltage J4 erroneous
F76
Door neither opens
nor closes. Invalid
sensors J4.1/2 detec-
ted
F77
Door neither opens
nor closes. Invalid
sensors J4.3/4 detec-
ted
Diagnosed cause
No connection to the DES. Check
motor connection cable and DES.
Internal test or membrane keypad
erroneous. Exchange membrane
keypad or control.
Internal test external button /
switch failed.
Check door mechanics / check
phases, motor connection cable.
Voltage supply error. Check
mains connection. Check peri-
pherals for short circuit.
Mains phases have been inver-
ted. Correct or re-adjust.
Return from pulsed operation to
dead man mode. Check closing
edge safety device and photo-
electric sensor.
Button actuated. Continuous
pulse pending. Check external
control devices (J1).
Duty cycle exceeded. Wait and let
motor cool down.
Speed monitor has tripped.
Check drive settings.
24 V failed. Check connections
on extended control.
Error occurred during self-testing.
Replace extended control.
Error occurred during self-testing.
Replace extended control.
No connection.
Module is not available, attach.
Replace battery.
Check contact resistances. Check
assembly of the wicket door con-
tact. Open and close wicket door,
check assembly.
Short circuit detected in the safety
circuit wicket door contact / slack
rope switch J4.1/2. Check cables
for short circuit, eliminate short
circuit.
Switch control on and off. If ne-
cessary, replace control.
Switch control on and off. If ne-
cessary, replace control.
Switch control on and off. Check
closing edge safety device, door
connection box for short circuit.
Check terminal assignment.
Check resistors. Check sensors.
Check resistors. Check sensors.
Error
State
F78
Drive blocks in end
position CLOSE
L
The access to the
menu was inhibited
by the authorized
specialist dealer.
Lo
Control has been in-
hibited.
U
The access to the
menu was unlocked
by the authorized
specialist dealer.
If the safety circuit is
interrupted, the warn-
ing indicator is illu-
minated, see
troubleshooting.
9

Maintenance

Tasks to be performed before starting maintenance
Hazardous voltage!
DANGER
Fatal electric shock when touching live parts. Ob-
serve the following safety rules when working on
the electrical system:
Disconnect from the mains.
Secure against inadvertent switch-on.
Verify de-energised state.
Work on the electrical system may only be
performed by skilled electricians or instruc-
ted persons working under the direction and
supervision of a skilled electrician in accord-
ance with the electrotechnical rules and dir-
ectives.
NOTICE
NOTICE
For your safety, we recommend that the door
system be checked before initial use and as
needed – at least once a year – in accordance
with the check list in the Inspection chapter. The
check can be carried out by a person with the
corresponding qualification certificate or by a
specialist company.
10

Disassembly

Disassembly is carried out in reverse order of the assembly in-
structions in the Installation chapter.
T100 R
Diagnosed cause
Check spring tension, check door
mechanics, check CLOSE end
position.
Contact specialist dealer. Menu
can only be unlocked by means
of the service tool.
Contact specialist dealer. Menu
can only be unlocked by means
of the service tool.